SIMH-C2

Place of use

These cables are used the places where are exposed high temperatures and low temperatures for lighting elements, tool and machines and furnaces, where are the environment temperatures are -60 C…+180 C. These cables are used industries such as iron and steel facilities and cement industries where mechanical impacts are slow.

Structure

Inner Conductor

Electrolytic Stranded Annealed Copper Wire,
IEC 60228, Class 5

Insulation

Slicon Compound EI2
VDE 0293; TS HD 308 S2 Colour Code

Stranding

Cores Twisted in Layers

Inner Sheath

Slicon Compound EM9, Terra-Cotta Colour

Screen

Tinned Copper Wire Braiding

Outer Sheath

Slicon Compound EM9, Terra-Cotta Colour

 

4@

Product Code Dimension and Weights Electrical Properties
Nominal Cross Section Overall Diemeter
( ~ )
Net Weight
( ~ )
Standart Lenght Max. Dc Conductor Resistance at 20◦ C Current Carrying Capacity
In Ground at 20° C On Air at 30° C

Technical Info


CONDUCTOR 
RESISTANCE

INSULATION
RESISTANCE
(MIN)

CURRENT 
CARRYING 
CAPACITY
OPERATING
VOLTAGE
TEST 
VOLTAGE
BENDING 
RADIUS
TEMPERATURE 
RANGE
FLAME RETARDANT 
TEST
mm²
0,75
1,0
1,5
2,5
4,0
Ω/km
26
19,5
13,3
7,98
4,95
MΩxKm
20
mm²
0,75
1,0
1,5
2,5
4,0
A
13
16
20
25
34
300/500 V2000 V6XD-60ºC+180ºCIEC 60332-1-2 
VDE 0482-332-1-2 
EN 60332-1-2
SMOKE DENSITY 
TEST
CORROSIVE GAS 
TEST
HALOGEN-FREE 
TEST
CIRCUIT INTEGRITY 
(FE 180)
FLAME 
PROPOGATION
IEC 61034-2
VDE 0482-1034-2 
EN 61034-2
BS EN 61034-2
IEC 60754-2
VDE 0482-267-2-3
EN 50267-2-3
BS EN 50267-2-3
IEC 60754-1
VDE 0482-267-2-1 
EN 50267-2-1
BS EN 50267-2-1
IEC 60331-21IEC 60332-3-24
VDE 0482-332-3-24
EN 60332-2-24

Catalog Info